 Double-Balanced Mixer, 500 KHz - 500 MHz
V 3.00
MD-124
Features
n n n n
FP-2
Usable down to 200 KHz Conversion Loss: 6.5 dB Typical Impedance: 50 Ohms Nominal Maximum Input Power: 300 mW max. @ 25C, Derated to 85C @ 3.2 mW/C n IF Port Current: 50 mA Max. n MIL-STD-883 Screening Available
Description
Transformers convert to the LO and RF paths to balanced lines connecting a low barrier, Schottky diode ring quad. These transformers help provide excellent isolation between ports. Conversion loss is low. The direct connection of the IF port to the diode quad allows these mixers to be used as phase detectors and bi-phase modulators.
Pin Configuration
Pin No. 1 2 3 4 Function GND GND GND IF Pin No. 5 6 7 8 Function LO GND GND RF
Electrical Specifications1: TA = -55C to +85C
Parameter Frequency Range Conversion Loss Isolation LO to RF 0.5 - 10 MHz 10 - 200 MHz 200 - 500 MHz 0.5 - 10 MHz 10 - 200 MHz 200 - 500 MHz 0.5 - 10 MHz 10 - 200 MHz 200 - 500 MHz -- -- Test Conditions RF, LO Ports IF Port Frequency 0.5 - 500 DC - 500 Units MHz MHz dB dB dB dB dB dB dB dB dB dB -- mV dBm dBm Min -- -- -- 35 30 25 30 25 20 25 15 15 -- -- -- -- Typ -- -- -- -- -- -- -- -- -- -- -- -- -- <3 +2 -2 Max -- -- 7.0 -- -- -- -- -- -- -- -- -- -- -- -- --
LO to IF
RF to IF
DC Polarity DC Offset RF Input
Negative -- 1 dB Compression 1 dB Desensitization
1. All specifications apply when operated at +7 dBm available LO power with 50 ohm source and load impedance.
Double-Balanced Mixer, 500 KHz - 500 MHz Electrical Specifications: TA = -55C to +85C
Parameter SSB Noise Figure Typical Two Tone IM Ratio Test Conditions Within 1 dB of Conversion Loss Max. With -10 dBm input, each input 25 MHz and 35 MHz IF Frequency -- 100 - 400 MHz 400 - 500 MHz Units -- dB dB Min -- -- -- Typ -- >50 >40
MD-124
V 3.00
Max -- -- --
Typical Performance Curves
Conversion Loss (LO = +7 dBm, RF = -5 dBm)
7
50 45
Isolation
LO - RF LO - IF RF - IF
Conversion Loss (dB)
Isolation (dB)
0.2 1 5 20 50 100 300 500 700
40 35 30 25
6
5
20 0.2 1 5 20 50 100 300 500 700
Frequency (MHz)
Frequency (MHz)
Conversion Loss vs. LO Power (LO = 35 MHz, RF = 30 MHz @ -20 dBm, IF = 5 MHz)
11 10
Ordering Information
Part Number MD-124 PIN Package FP-2
Loss (dB)
9 8 7 6 5 -10.0 -7.5 -5.0 -2.5 0.0 2.5 5.0 7.5 10.0
LO Power (dBm)
Specifications subject to change without notice. n North America: Tel. (800) 366-2266 n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298 n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.
2


▲Up To Search▲   

 
Price & Availability of MD-124PIN

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X